Mass Spectrometers
Location: Silver 717, Silver 840
- This instrument is designed to deliver state-of-the-art performance for API (Atmospheric Pressure Ionization)-LCMS applications for polar samples
- The total concentration of sample injected into the system is in the pmol/µl range with a LC flow rate up to 1000 µL per minute
Accessories
- Vacuum degasser
- Quadruple pump
- Well-plate auto-sampler
- Diode array and multiple wavelength detector (DAD)
- Single quadrupole mass selective detector with a maximum mass range of 2,000 amu
- ESI ionization source
- APCI (Atmospheric Pressure Chemical Ionization) source for wide range of samples with less polarity
** NOTE: The instrument in Silver 840 has no column-loop selection valve, therefore only column runs are allowed. Strongly recommend for users to user their own columns. **
The Agilent 6120 Single Quadrupole LCMS Spectrometer was acquired through the support of New York University
Location: Silver 717
This instrument is provides numerous benefits including:
- Robust performace with their Active Ion Management technology
- High sensitivity using a segmented hyperbolic-surface quadrupoles
- Ultrafast selected monitoring capabilities
- Easy to use software for increased productivity
Features:
- Mass range: m/z 5 - 3000
- Resolution: Q1 adjustable to 0.4 Da peak width
- Scan Rate: 15000 amu/s at resolution 2Da, up to 600 SRMs/sec for resolution between 0.4 and 2.0 FWHM
- Mass Stability: Mass assignments within +/- 0.1 Da
The ThermoScientific LC/MS TSQ Spectrometer was acquired through the support of New York University
Location: Silver 717
- This instrument is a high-definition mass spectrometer capable of delivering exceptional sensitivity and excellent sub 1-ppm mass accuracy
Accessories
- Vacuum degasser
- Binary pump
- Well-plate auto-sampler
- Diode array and multiple wavelength detector (DAD)
- Time of Flight (TOF) mass selective detector with a mass range of 20,000 m/z
- Duo-ESI ionization source
- APCI (Atmospheric Pressure Chemical Ionization) source for wide range of samples with less polarity
The Agilent 6224 TOF LC/MS Mass Spectrometer was acquired through the support of New York University
Location: Silver 717
- This instrument is a triple quadrupole system designed for smart productivity for high efficiency sample throughput, quick and easy method development, and for low detection limits and Scan/MRM
- Comes with Electron Impact (EI), Chemical Ionization (CI), and Negative Chemical Ionization (NCI) modes of operation from 10 to 1090 amu and a mass resolution of 0.5 – 3.0 amu
Accessories
- 150 vial autosampler
- Triple quadrupole MS detector
- FID detector
The Shimadzu GCMS-TQ8040 Spectrometer was acquired through the support of New York University
Location: Brown 353A
- Innovative MALDI-TOF and TOF/TOF technology optimized for robustness enables reliable and detailed protein/peptide characterization, polymer analysis, MALDI tissue imaging, glycan analysis, and high-throughput biochemical screening.
- The autoflex maX uses Bruker's proprietary smartbeam-II solid state laser. With repetition rates up to 2kHz, higher throughput workflows including product integrity screening or thin layer chromatography coupled to MALDI are rapidly executed.
- The smartbeam II solid state laser also provides best-in class ionization efficiency and low sample consumption promoting high spot capacity for complex samples.
- Specifications:
- Resolution: 26,000
- Mass range: up to 500,000
- Mass Accuracy: 2 ppm
- Laser Frequency: 2,000 (MS) 200 (TOF/TOF)
The Bruker autoflex maX MS was acquired through the support of New York University